If you need more than 10pcs and want to get better wholesale price, please feel free to contact Mr.Brook by following:
email:service@fasttobuy.com
Tel:0086-755- 82546545
We will quote you our best price to you in 24hours.
Delta PLC (programmable logic controller) EX series:
Features
The EX series is the analog MPU with the lowest cost. Apart from supporting digital input and output, the EX series has built-in multiple analog I/O channels and integrates a variety of communication protocol’s for constructing a complete control network. EX series is suitable for all kinds of small PLC applications.
Specifications
*MPU points: 20 (8DI/6DO, 4AI/2AO)
*Max. I/O points: 238
*Program capacity: 4K Steps
*Communication port: Built-in RS-232 and RS-485, compatible with MODBUS ASCII / RTU communication protocol.
*High-speed pulse output: Supports 2-point (Y0, Y1) independent high-speed pulse output of up to 10KHz.
*Built-in 4-point high-speed counter
1 phase 1 |
1 phase 2 |
2 phase 2 |
|||
group |
Bandwidth |
group |
Bandwidth |
group |
Bandwidth |
2/2 |
20kHz/10kHz |
1 |
20kHz |
1 |
4kHz |
#Bandwidth refers to the max. counting range of a single counter.
*Built-in analog I/O function
Analog Input |
Analog Output |
||
Points |
4 |
Points |
2 |
Resolution |
10-Bit |
Resolution |
8-Bit |
Spec. |
-20 ~ 20mA or -10 ~ 10V |
Spec. |
0 ~ 20mA or 0 ~ 10V |
Model Item |
DVP- 14ES00_ |
DVP- 24ES00_ |
DVP- 30ES00_ |
DVP- 32ES00_ |
DVP- 40ES00_ |
DVP- 60ES00_ |
DVP- 20EX00_ |
DVP- 24ES11_ |
DVP- 20EX11_ |
Power Supply Voltage |
100 ~ 240V AC (-15% ~ 10%), 50/60Hz + - 5% |
24V DC (-15% ~ 10%) |
|||||||
Operation Specification |
The PLC start to operate at power supply of 95 ~ 100V AC. If the voltage of power supply drops to 70V AC, the PLC will stop. Maximum power loss time is 10ms or less. |
Maximum power loss time is 5ms or less. |
|||||||
Fuse |
2A/250V AC |
||||||||
Power Consumption |
20VA |
25VA |
30VA |
30VA |
30VA |
35VA |
30VA |
6.5W |
8W |
DC24V Supply Current |
400mA |
/ |
|||||||
Power Protection |
DC24V output short circuit |
DC24V input polarity |
|||||||
Voltage Withstand |
1,500 VAC (Primary-secondary), 1,500V AC (Primary-PE), 500V AC (Secondary-PE) |
||||||||
Insulation Resistance |
> 5 M Ohm at 500V DC (Between all inputs/outputs and earth) |
||||||||
Noise Immunity |
ESD: 8KV Air Discharge EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V RS: 26MHz ~ 1GHz, 10V/m |
||||||||
Grounding |
The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and N (All DVP units should be grounded directly to the ground pole). |
||||||||
Environment |
Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), Pollution degree2 Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity) |
||||||||
Vibration / Shock Resistance |
Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea) |
||||||||
Weight (g) |
400 |
552 |
580 |
580 |
596 |
750 |
536 |
414 |
386 |
Applications
USED for packaging machine, spinning machine, conveyer belt (rotation speed control), winding machine (tension control), food processing machine, landscape fountain.
Other hot items of this EX series PLC for above applications:
DVP30EX200R |
Delta PLC EX series DVP30EX200R 30 point 16DI/10DO (relay) 3AI/1AO New Free shipping |
DVP30EX200T |
Delta PLC EX series DVP30EX200T 30 point 16DI/10DO (NPN transistor) 3AI/1AO New Free shipping |
Tell us what you think about this item, share your opinion with other people. Please make sure that your review focus on this item. All the reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.
Have any question or inquire for this item? Please contact us. Our customer representative will get back shortly.